Product Description

Commercial Grade Motorized Dual Motor Sit Stand Desk Base
Specification

Height range 620-1270mm
Base width 1100-1700mm
Speed noise < 50dB
Load Capacity 120kg
Speed 35mm/s
Material Q235 Steel
Input Voltage AC 110V-220V
Output voltage DC 24V
Duty Cycle Max.10%
Frame color Black White Grey
Warranty 5 years
GW/NW 27/25kg
Packing info Individual packing: 1080*270*235mm
20GP/40GP/40HQ: 400PCS/800PCS/1000PCS
Function 1. Soft Start/Stop Feature 
2. Anti-Collision Feature 
3. Metric and Inch Switch 
4. Four-Position Height Memory 
5., Overheat/Overload Protection 
6. Leg Unbalance Protection
7. With USB Charging Port
8. Setting the Upper & Lower Height Limits
9. Sit/Stand Time Reminder

Product Display

1. Quick and smooth adjustment: Smooth lifting with a speed of 1 inch/sec. Flexible working posture, from sitting to standing. Make work easier and more comfortable
2. Stretch length adjustment: It is suitable for various spaces and desktop sizes. You can choose the desktop according to your preferences.
3. Quality steel: Sturdy base eliminates wobble, The table frame is made of 1.5tmm cold-rolled carbon steel same as automobiles. Strong, long-lasting, resists compression, and does not change shape.
4. Powerful dual-motor: High-power energy-saving motor system, quiet and stable, creating a comfortable working and learning environment
5. Memory function: Long press the 1234 key to update the memory, short press it to automatically rise to the memory height.?
6. Control box: Control boxes work with the UP series desk. It has low energy consumption, is small in size is lightweight, beautiful appearance, and is easy to mount (grooves in the bottom).

Product Dimension

Products Application

Company Profile
The company has introduced advanced linear actuator research and development technology and domestic talents in the field and has applied for dozens of patent technologies, some of which have been successfully applied in office, home, solar energy, and other domain. The company has passed the national ISO9001 quality system, and the products have been awarded CE, TUV, UL, BIFMA5.5, and other certificates. In order to provide good customer service, we have purchased a large number of all kinds of experimental and testing equipment. At present, we have more than 10 R&D engineers in machinery, electronics, structure, products, and other fields. Our long-term goal is to satisfy the market customers and keep improving and doing well in technical research and development. The company has its own independent brand and trademark and has established a sales team of domestic and foreign trade with foreign consultants. At present, its products have been exported to more than 30 countries and regions, especially to Europe, America, and Australia. CHINAMFG leads the way in creating great experiences by offering a range of height-adjustable desks, linear actuators,s and sheet metal products, and services designed to help people reach their full potential. Our comprehensive portfolio is anchored by the UPLIFTEC brand, which registered a trademark with 5 patent applications in China. Together with our partners, we design spaces to help people work, learn and heal. We drive sustainable social, economic, and environmental change through our decisions and actions. At UPLIFT, we don’t just do what’s right, we do what’s best – for people and for the planet.

Packing and shipping
Outer packing: The outer layer is shockproof / moisture imitation paper layer packaging, thickened 5 layers of corrugated paper, etc. to protect your furniture in the whole process and ensure the safety of products in transportation
Inner packing: The inner layer is anticollision, thickening, laminating, foam package, strong and wear-resistant, not easy to deform, to ensure the safety of goods in transit.
Packing info: Individual packing: 1080(L)*270(W)*236(H)mm, 20GP/40GP/40HQ: 400PCS/800PCS/1000PCS

FAQ

1. What are your main products?
Our main products have dual motor two/three segments standing desk, single motor standing desk, L-shape standing desk, standing desk workstation, and electric lifting column.

2. What color choices are available with a standing desk?
A: The most popular colors are black, white, and grey (silver), but we can provide custom colors as requested. 

3. Do your products support customization?
Our R&D team can customize products that exactly meet your requirements.

4. Do you offer a warranty for the products?
Yes, we offer a 5~10 years warranty on most of the products.

5. How many sets of products can fit in a 20ft/40ft container?
A 20ft/40ft container can fit in a 340/700 sets dual motor desk frame (with pallets) and can fit in 420/880 sets dual motor desk frame (without pallets).
A 20ft/40ft container can fit in 480/992 sets single motor desk frame (with pallets) and can fit in 592/1216 sets single motor desk frame (without pallets).

Style: Modern
Material: Metal
Wood Style: Panel
Samples:
US$ 150/Piece
1 Piece(Min.Order)

|

Order Sample

Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

motor base

Are there specific safety considerations associated with motor base installation?

Motor base installation involves specific safety considerations that should be taken into account. Here’s a detailed explanation:

1. Electrical Safety: When installing a motor base, it is crucial to ensure proper electrical safety measures. This includes disconnecting power sources, following lockout/tagout procedures, and wearing appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses. It is important to work with qualified personnel who are knowledgeable about electrical safety practices.

2. Lifting and Rigging Safety: Motor bases can be heavy, especially when combined with the weight of the motor. During installation, it is essential to use proper lifting and rigging techniques to prevent accidents or injuries. This may involve using appropriate lifting equipment, such as cranes or hoists, and ensuring that the motor base is securely attached to the lifting apparatus.

3. Structural Integrity: Motor bases need to be properly installed on a stable and structurally sound foundation. Ensure that the mounting surface can support the weight of the motor and base without any risk of collapse or instability. If necessary, consult with a structural engineer to assess the adequacy of the installation site and make any required modifications.

4. Secure Fastening: Properly and securely fasten the motor base to the mounting surface using appropriate bolts, screws, or anchors. Follow the manufacturer’s recommendations for torque specifications to ensure secure fastening without overloading or damaging the base. Loose or inadequate fastening can lead to instability and potential accidents.

5. Ergonomics: Consider ergonomic factors during motor base installation to prevent strain or injury to personnel. Use proper lifting techniques, provide adequate lifting aids or equipment, and ensure that the work area is free from clutter or obstacles. This helps reduce the risk of musculoskeletal injuries during the installation process.

6. Environmental Hazards: Evaluate the installation site for any potential environmental hazards that could affect safety. This includes identifying and mitigating risks such as slippery surfaces, obstructions, or the presence of chemicals or hazardous materials. Take appropriate precautions to ensure a safe working environment for the installation personnel.

7. Manufacturer Guidelines: Follow the manufacturer’s guidelines and instructions for motor base installation. These guidelines often include specific safety considerations and precautions that are relevant to the particular motor base model. Adhering to the manufacturer’s recommendations helps ensure safe and proper installation.

8. Inspections and Testing: After the motor base installation, conduct thorough inspections and testing to verify the integrity of the installation and ensure proper functionality. This includes checking for any loose connections, verifying proper alignment, and performing electrical tests as required. Regular inspections and testing also play a crucial role in ongoing maintenance and safety of the motor base.

It is important to note that the specific safety considerations may vary depending on factors such as the size and type of motor, the installation site, and applicable regulations. It is recommended to consult with experts in motor base installation and adhere to relevant safety standards and guidelines to ensure a safe and compliant installation process.

motor base

How can users troubleshoot common issues related to motor base misalignment?

Troubleshooting common issues related to motor base misalignment can help ensure optimal performance and prevent potential problems. Here’s a detailed explanation:

1. Visual Inspection: Start by visually inspecting the motor base and its alignment with the driven equipment. Look for any obvious signs of misalignment, such as gaps, uneven contact, or skewed positioning. Pay attention to the alignment of coupling or drive belts, as they can indicate misalignment issues as well.

2. Measurements and Alignment Tools: Use precision measurement tools such as dial indicators, laser alignment devices, or straightedges to assess the alignment of the motor base. These tools can provide accurate measurements and help identify misalignment issues. Measure the alignment at multiple points along the motor base and compare the readings to the manufacturer’s recommended tolerances.

3. Check Mounting Bolts and Fasteners: Loose or improperly tightened mounting bolts and fasteners can contribute to motor base misalignment. Ensure that all bolts and fasteners are securely tightened according to the manufacturer’s specifications. If any bolts are found to be loose, tighten them appropriately. However, be cautious not to overtighten, as it can lead to deformation or misalignment of the motor base.

4. Assess Foundation or Mounting Surface: Examine the foundation or mounting surface on which the motor base is installed. Uneven or unstable surfaces can cause misalignment. Check for any irregularities, such as cracks, gaps, or soft spots, that may affect the alignment of the motor base. If necessary, repair or reinforce the foundation to ensure a stable and level mounting surface.

5. Alignment Adjustment: If misalignment is detected, make the necessary adjustments to bring the motor base into proper alignment. This may involve loosening the mounting bolts, adjusting shims or wedges, and repositioning the motor base. Follow the manufacturer’s guidelines or consult alignment experts for specific adjustment procedures based on the type of motor base and alignment method used.

6. Consider Thermal Growth: Account for thermal growth when aligning the motor base. Motors can experience thermal expansion or contraction during operation, which can affect alignment. Consult the manufacturer’s recommendations for thermal growth allowances and adjust the alignment accordingly.

7. Regular Maintenance: Implement a regular maintenance program that includes periodic inspections and realignment of the motor base. Over time, environmental factors, operational stresses, or equipment vibrations can cause misalignment. Regular maintenance helps identify and address misalignment issues before they escalate and lead to more severe problems.

8. Professional Assistance: If troubleshooting and adjustments do not resolve the misalignment issues, or if the alignment task requires specialized knowledge and equipment, seek assistance from alignment professionals or qualified technicians. They have the expertise and tools to accurately diagnose and correct complex misalignment problems.

It’s important to note that proper alignment of the motor base is essential for the smooth and efficient operation of the entire system. Misalignment can result in increased wear and tear, reduced energy efficiency, excessive vibration, premature component failure, and decreased overall performance. By promptly addressing misalignment issues, users can optimize the performance and lifespan of their motor base and associated equipment.

motor base

How does a motor base contribute to the stability and alignment of electric motors?

A motor base plays a crucial role in contributing to the stability and alignment of electric motors in industrial applications. Here’s a detailed explanation:

A motor base, also known as a motor mounting base or motor support base, provides essential support and alignment features that help ensure the stable and properly aligned positioning of electric motors. Here’s how a motor base contributes to stability and alignment:

1. Support and Weight Distribution: A motor base serves as a robust platform to support the weight of the electric motor. It helps distribute the motor’s weight evenly across the base, preventing excessive stress or strain on the motor and its mounting points. By providing adequate support, the motor base helps maintain the motor’s structural integrity and prevents any sagging or tilting that could lead to misalignment.

2. Adjustable Mounting Features: Motor bases often include adjustable features such as slotted holes or bolt patterns that allow for precise alignment of the motor. These adjustment options enable technicians to align the motor with connected equipment, such as pumps, fans, conveyors, or gearboxes. Proper alignment is crucial for efficient power transmission, minimizing wear and tear on the motor and connected components, and reducing the risk of mechanical failures.

3. Rigid Construction: Motor bases are typically constructed from sturdy materials like steel or cast iron, which provide rigidity and stability. The robust construction of the motor base helps absorb and dampen vibrations generated during motor operation, minimizing the transmission of vibrations to the surrounding equipment or structure. This vibration control contributes to the overall stability of the motor and its surrounding components.

4. Alignment Verification: Motor bases often include alignment verification features such as laser alignment systems or dial indicators. These tools assist technicians in precisely aligning the motor with connected equipment. By using these verification methods, technicians can ensure that the alignment is within specified tolerances, further enhancing stability and minimizing the risk of misalignment-related issues.

5. Secure Mounting: Motor bases are designed to securely attach the motor to the base, typically using bolts or fasteners. This secure mounting prevents any movement or shifting of the motor during operation, enhancing stability. It also helps maintain the alignment achieved during the installation process.

By providing support, adjustable alignment features, rigidity, alignment verification, and secure mounting, motor bases contribute significantly to the stability and alignment of electric motors in industrial applications. Proper stability and alignment are essential for optimal motor performance, reduced wear and tear, improved energy efficiency, and prolonged motor lifespan.

When installing a motor base, it’s crucial to follow manufacturer guidelines and ensure proper anchoring to the foundation or supporting structure. This helps maintain the integrity of the motor base and ensures the reliable operation of the motor.

In summary, a motor base is a critical component that contributes to the stability and alignment of electric motors by providing support, alignment adjustability, rigidity, alignment verification, and secure mounting, ultimately enhancing motor performance and reliability.

China OEM Commercial Grade Motorized Dual Motor Sit Stand Desk Base   supplier China OEM Commercial Grade Motorized Dual Motor Sit Stand Desk Base   supplier
editor by CX 2023-11-30